Metrology Lead
Vulcan Elements · Vulcan Elements is a manufacturer of rare-earth magnets used in critical defense and commercial applications.
Research Triangle Park, NC51-100 employeesPosted 3 days ago
Venture - Series Unknown · $431Mraised 6 months agoled by nvp capital, Washington Harbour Partners, FJ Labs
This board only lists companies whose most recent round closed in the last 180 days.
<p><span data-contrast="auto">Vulcan Elements is manufacturing American rare-earth permanent magnets for a secure, resilient future. With a focus on national security and economic resiliency, we serve critical industries such as defense, aerospace, and automotive powering a high-technology future. Vulcan Elements is building a team of ambitious professionals committed to Mission Focus, Technical Excellence and Transparency.</span><span data-ccp-props="{}"> </span></p>
<p><span data-contrast="auto">Initially supporting Pilot operations in Durham, then transitioning and moving to Benson (early 2027), the Metrology Lead is responsible for developing and managing the company's measurement systems to ensure product quality from development through high-volume manufacturing. This role serves as the owner for metrology strategy, partnering closely with the Analytical Laboratory, R&D, Engineering, Manufacturing, and Supply Chain.</span><span data-ccp-props="{}"> </span></p>
<p><span data-contrast="auto">The role focuses on ensuring that critical product and process characteristics outlined in the Control Plan can be measured accurately, repeatably, and efficiently throughout the product lifecycle. This includes defining measurement requirements, selecting and qualifying metrology equipment, developing inspection methods, performing Measurement System Analysis (MSA), implementing Statistical Process Control (SPC), and transferring qualified measurement systems from Pilot to Benson manufacturing.</span><span data-ccp-props="{}"> </span></p>
<p><strong><span data-contrast="none">Responsibilities</span></strong><span data-ccp-props="{"134233117":true,"134233118":true,"201341983":0,"335557856":16777215,"335559740":240}"> </span></p>
<p><strong><span data-contrast="auto">Analytical </span></strong><strong><span data-contrast="auto">Measurement Strategy</span></strong><span data-ccp-props="{"335559739":0}"> </span></p>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="5" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="1" data-aria-level="1"><span data-contrast="auto">Assess current </span><span data-contrast="auto">analytical and </span><span data-contrast="auto">metrology capabilities against product, process, and customer requirements.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="5" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="2" data-aria-level="1"><span data-contrast="auto">Develop the company's metrology roadmap to support Pilot operations and future high-volume manufacturing.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="5" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="3" data-aria-level="1"><span data-contrast="auto">Define measurement requirements for Critical-to-Quality (CTQ) characteristics identified through PFMEAs and Control Plans.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="5" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="4" data-aria-level="1"><span data-contrast="auto">Define measurement methods and sampling plans within Control Plans.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="5" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="5" data-aria-level="1"><span data-contrast="auto">Ensure measurement capability supports process capability objectives and production readiness.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="5" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="6" data-aria-level="1"><span data-contrast="auto">Identify capability gaps and recommend appropriate internal vs. external testing strategies.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<p><strong><span data-contrast="auto">Measurement Systems Analysis</span></strong><strong><span data-contrast="auto"> </span></strong><strong><span data-contrast="auto">& Equipment Qual</span></strong><strong><span data-contrast="auto">ification</span></strong><span data-ccp-props="{"335559739":0}"> </span></p>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="7" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="1" data-aria-level="1"><span data-contrast="auto">Lead selection, specification, procurement, installation, and qualification of </span><span data-contrast="auto">analytical and </span><span data-contrast="auto">metrology equipment.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="7" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="2" data-aria-level="1"><span data-contrast="auto">Develop equipment qualification protocols</span><span data-contrast="auto">,</span><span data-contrast="auto"> </span><span data-contrast="auto">and </span><span data-contrast="auto">acceptance criteria</span><span data-contrast="auto"> amd commissioning plans.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="7" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="3" data-aria-level="1"><span data-contrast="auto">Support equipment vendor selection, technical evaluation, RFQs, and capital purchase decisions.</span><span data-contrast="auto">.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="7" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="4" data-aria-level="1"><span data-contrast="auto">Develop and execute IQ/OQ/PQ or equivalent equipment qualification and validation activities, as appropriate.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="7" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="5" data-aria-level="1"><span data-contrast="auto">Develop and validate inspection and measurement methods in collaboration with the Analytical Laboratory</span><span data-contrast="auto"> and Engineering</span><span data-contrast="auto">.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="7" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="6" data-aria-level="1"><span data-contrast="auto">H</span><span data-contrast="auto">elp to p</span><span data-contrast="auto">erform</span><span data-contrast="auto">Lead or support</span><span data-contrast="auto"> Gauge R&R, bias, linearity and stability</span><span data-contrast="auto">, and other MSA</span><span data-contrast="auto"> </span><span data-contrast="auto">studies.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="7" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="7" data-aria-level="1"><span data-contrast="auto">Establish measurement uncertainty where appropriate.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="7" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="8" data-aria-level="1"><span data-contrast="auto">Ensure appropriate calibration, preventive maintenance, and lifecycle management of </span><span data-contrast="auto">analytical and </span><span data-contrast="auto">quality inspection equipment.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<p><strong><span data-contrast="auto">Statistical Quality</span></strong><span data-ccp-props="{"335559739":0}"> </span></p>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="9" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="1" data-aria-level="1"><span data-contrast="auto">Support the development and implementation of SPC strategies for operation.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="9" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="2" data-aria-level="1"><span data-contrast="auto">Support process capability studies (Cp, Cpk).</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="9" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="3" data-aria-level="1"><span data-contrast="auto">Analyze quality </span><span data-contrast="auto">and analytical </span><span data-contrast="auto">data and identify opportunities for process</span><span data-contrast="auto">.</span><span data-contrast="auto"> </span><span data-contrast="auto">improvement.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<p><strong><span data-contrast="auto">Analytical </span></strong><strong><span data-contrast="auto">Method Development & </span></strong><strong><span data-contrast="auto">Equipment </span></strong><strong><span data-contrast="auto">Transfer</span></strong><span data-ccp-props="{"335559739":0}"> </span></p>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="10" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="1" data-aria-level="1"><span data-contrast="auto">Lead development, optimization, and validation of analytical and measurement methods for new and existing products and processes</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="10" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="2" data-aria-level="1"><span data-contrast="auto">Lead transfer of qualified analytical and inspection methods from Pilot to Benson.</span><span data-contrast="auto">Standardize measurement methods across facilities</span><span data-contrast="auto">.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="10" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="3" data-aria-level="1"><span data-contrast="auto">Lead installation and qualification of analytical and metrology equipment at the Benson facility.</span><span data-contrast="auto">Lead </span><span data-contrast="auto">installation, and qualification of metrology equipment</span><span data-contrast="auto"> in Benson facility.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="10" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="4" data-aria-level="1"><span data-contrast="auto">Lead transfer of qualified inspection methods from Pilot to Benson.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="10" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="4" data-aria-level="1"><span data-contrast="auto">Create SOPs, work instructions, training materials, and other documentation required for implementation.</span><span data-contrast="auto">Create SOPs, work instructions, and training materials.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<p><strong><span data-contrast="auto">Compliance & Continuous Improvement</span></strong><span data-ccp-props="{"335559739":0}"> </span></p>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="11" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="1" data-aria-level="1"><span data-contrast="auto">Support ISO 9001 implementation and measurement-related processes.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="11" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="2" data-aria-level="1"><span data-contrast="auto">Develop laboratory and metrology practices consistent with ISO/IEC 17025 principles where applicable.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="11" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="3" data-aria-level="1"><span data-contrast="auto">Support internal audits, customer audits, and continuous improvement initiatives.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<p><span data-ccp-props="{}"> </span></p>
<p><em><span data-contrast="auto">Responsibilities and tasks outlined are not exhaustive and may change as determined by the needs of the business</span></em><span data-ccp-props="{}"> </span></p>
<p><strong><span data-contrast="none">Qualifications</span></strong><span data-ccp-props="{"134233117":true,"134233118":true,"201341983":0,"335557856":16777215,"335559740":240}"> </span></p>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="12" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="1" data-aria-level="1"><span data-contrast="auto">Bachelor's degree in Chemistry, Engineering, Materials Science, Physics, or related technical discipline.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="12" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="2" data-aria-level="1"><span data-contrast="auto">7+ years of experience in manufacturing quality, metrology, or measurement systems, with reduced experience requirements for candidates holding advanced degrees (M.S. or Ph.D.)</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="12" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="3" data-aria-level="1"><span data-contrast="auto">Strong experience in analytical method development.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="12" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="4" data-aria-level="1"><span data-contrast="auto">Strong experience with MSA and SPC.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="12" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="5" data-aria-level="1"><span data-contrast="auto">Experience selecting and qualifying metrology equipment.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="12" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="6" data-aria-level="1"><span data-contrast="auto">Working knowledge of ISO 9001 and measurement system requirements.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="12" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="7" data-aria-level="1"><span data-contrast="auto">Familiarity with ISO/IEC 17025 laboratory principles.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="12" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="8" data-aria-level="1"><span data-contrast="auto">Experience supporting new product introduction and manufacturing scale-up.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<ul>
<li data-leveltext="" data-font="Symbol" data-listid="12" data-list-defn-props="{"335552541":1,"335559685":720,"335559991":360,"469769226":"Symbol","469769242":[8226],"469777803":"left","469777804":"","469777815":"multilevel"}" data-aria-posinset="9" data-aria-level="1"><span data-contrast="auto">Excellent statistical analysis and problem-solving skills.</span><span data-ccp-props="{"335559739":0}"> </span></li>
</ul>
<p><em><span data-contrast="auto">Must be a U.S. Person due to required access to U.S. export-controlled information or facilities.</span></em> <br><span data-ccp-props="{"335559739":0}"> </span></p>
Apply on Vulcan Elements’s site
Applications go straight to the employer. VCBacked does not sit between you and the company.